Sampling Requirements

Prior to testing, the designated laboratory must collect a representative sample from each batch of product. Depending on the product type and batch size, a specified number of increments or “subsamples” must be taken from different areas of the batch to obtain a representative sample ready to be tested. These increment amounts can be found in the charts below.

Harvest Batch Size

The representative sample must weigh a minimum of 0.35% of the total harvest batch weight.

The harvest batch must weight less than 50 pounds.

Batch Size (lbs) Increments
≤ 10 8
10.1-20 16
20.1-30 23
30.1-40 29
40.1-50 34

Manufactured Products Batch Size

The product batch or pre-roll batch must contain no more than 150,000 units.

The number of increments listed are minimum amounts. Each sample increment consists of 1 packaged unit.

Batch Size (units) Increments (min) Batch Size (units) Increments (min)
≤ 50 2 1,201 – 3,200 13
51 – 150 3 3,201 – 10,000 20
151 – 500 5 10,001 – 35,000 32
501 – 1200 8 35,001 – 150,000 50